Effect of Glass Fiber Post Diameter on Fracture Resistance of Endodontically Treated Teeth

Authors

  • Saied Nokar
  • Mahsa Sadat Mortazavi
  • Somayeh Niakan

Keywords:

Post and Core Technique, Tooth, Nonvital, Flexural Strength

Abstract

Objective: To determine the fracture resistance of endodontically treated teeth restored with three different diameters of glass fiber posts and metal-ceramic crowns. Material and Methods: Thirty human maxillary canines were selected and subjected to root canal therapy. The teeth were randomly divided into three groups of glass fiber posts with 1.4 mm diameter (Group I), 1.6 mm diameter (Group II), and 2.0 mm diameter (Group III). The teeth were restored with metal-ceramic crowns and subjected to the compressive load applied at 45° angle to the longitudinal axis until fracture. The mode of failure was determined. Data were analyzed using ANOVA, followed by Tukey's post hoc multiple comparisons test (p<0.05). Results: The mean fracture resistance of groups I, II and III was 574 ± 91.2 N, 617 ± 85.21 N and 467 ± 99.43 N, respectively. No significant difference was noted between groups I and II, while the fracture resistance was significantly different between groups I and III (p<0.05) and groups II and III (p<0.05). No case of post fracture alone occurred in any group. Conclusion: The diameter of glass fiber posts can affect the fracture resistance of teeth. Based on the results, increasing the diameter of the post up to 1.6 mm may increase the fracture resistance of root, although excessive diameters are not recommended.

References

Sadeghi M. A comparison of the fracture resistance of endodontically treated teeth using three different post systems. J Dent Tehran Univ Med Sci 2006; 3(2):69-76.

Sharafeddin F, Alavi AA, Zare S. Fracture resistance of structurally compromised premolar roots restored with single and accessory glass or quartz fiber posts. Dent Res J 2014; 11(2):264-71.

Fernandes AS, Shetty S, Coutinho I. Factors determining post selection: a literature review. J Prosthet Dent 2003; 90(6):556-62. https://doi.org/10.1016/j.prosdent.2003.09.006

Nandini VV, Venkatesh V. Current concepts in the restoration of endodontically treated teeth. J Indian Prosthod Soc 2006; 6(2):63-7. https://doi.org/10.4103/0972-4052.27776

Sahafi A, Peutzfeldt A, Asmussen E, Gotfredsen K. Retention and failure morphology of prefabricated posts. Int J Prosthodont 2004; 17(3):307-12.

Turker SB, Alkumru HN, Akalin B. Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns. J Adv Prosthodont 2016; 8(2):158-66. https://doi.org/10.4047/jap.2016.8.2.158

Dastjerdi MR, Chaijan KA, Tavanafar S. Fracture resistance of upper central incisors restored with different posts and cores. Restor Dent Endod 2015; 40(3):229-35. https://doi.org/10.5395/rde.2015.40.3.229

Kaur J, Verma PR, Sharma N, Kinra M. Review of stresses around post restorations – an insight view through finite element analysis. IOSR J Dent Med Sci 2015; 14(2):75-9.

Assif D, Gorfil C. Biomechanical considerations in restoring endodontically treated teeth. J Prosthet Dent 1994; 71(6):565-7. https://doi.org/10.1016/0022-3913(94)90438-3

Lloyd PM, Palik JF. The philosophies of dowel diameter preparation: a literature review. J Prosthet Dent 1993; 69(1):32-6. https://doi.org/10.1016/0022-3913(93)90236-h

Ranjbar M, Noudeh GD, Hashemipour MA, Mohamadzadeh I. A systematic study and effect of PLA/Al2O3 nanoscaffolds as dental resins: mechanochemical properties. Artif Cells Nanomed Biotechnol 2019; 47(1):201-9. https://doi.org/10.1080/21691401.2018.1548472

Ranjbar M, Pardakhty A, Tahmipour B, Mohamadzadeh I. Novel CaO/polylactic acid nanoscaffold as dental resin nanocomposites and the investigation of physicochemical properties. Luminescence 2019; 34(3):360-7. https://doi.org/10.1002/bio.3617

Eskandarizadeh A, Parizi MT, Goroohi H, Badrian H, Asadi A, Khalighinejad N. Histological assessment of pulpal responses to resin modified glass ionomer cements in human teeth. Dent Res J 2015; 12(2):144-9.

Rekabi AR, Ashouri R, Torabi M, Parirokh M, Abbott PV. Florid cemento‐osseous dysplasia mimicking apical periodontitis: a case report. Aust Endod J 2013; 39(3):176-9. https://doi.org/10.1111/j.1747-4477.2011.00325.x

Hashemipour MA, Ghasemi AR, Dogaheh MA, Torabi M. Effects of locally and systemically applied n-3 fatty acid on oral ulcer recovery process in rats. Wounds 2012; 24(9):258-66.

Gu XH, Huang JP, Wang XX. An experimental study on fracture resistance of metal-ceramic crowned incisors with different post-core systems. Zhonghua Kou Qiang Yi Xue Za Zhi 2007; 42(3):169-72.

Maccari PC, Cosme DC, Oshima HM, Burnett LH, Shinkai RS. Fracture strength of endodontically treated teeth with flared root canals and restored with different post systems. J Esthet Restor Dent 2007; 19(1):30-6.

Rolland SL, Carrick TE, Walls AW, McCabe JF. Dentin decontamination using chloramine T prior to experiments involving bacteria. Dent Mater 23(12):1468-72.

Monzavi A, Nokar S, Javadi HR. The effects of post diameter on stress distribution in maxillary central incisor, a three dimensional finite element study. J Dent Tehran Univ Med Sci 2004; 1(2):17-23.

Adanir N, Belli S. Evaluation of different post lengths’ effect on fracture resistance of a glass fiber post system. Eur J Dent 2008; 2:23-8.

Al-Wahadni AM, Hamdan S, Al-Omiri M, Hammad MM, Hatamleh MM. Fracture resistance of teeth restored with different post systems: in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106(2):e77-83. https://doi.org/10.1016/j.tripleo.2008.03.038

Torabinejad M, Walton RE. Endodontics: Principles and Practice. London: Elsevier Health Sciences; 2009. 474pp.

Abduljabbar T, Sherfudhin H, AlSaleh SA, Al-Helal AA, Al-Orini SS, Al-Aql NA. Fracture resistance of three post and core systems in endodontically treated teeth restored with all-ceramic crowns. King Saud Univ J Dent Sci 2012; 3(1):33-8. https://doi.org/10.1016/j.ksujds.2011.10.001

Maccari PC, Conceicao EN, Nunes MF. Fracture resistance of endodontically treated teeth restored with three different prefabricated esthetic posts. J Esthet Restor Dent 2003; 15(1):25-30.

Lassila LV, Tanner J, Le Bell AM, Narva K, Vallittu PK. Flexural properties of fiber reinforced root canal posts. Dent Mater 2004; 20(1):29-36. https://doi.org/10.1016/s0109-5641(03)00065-4

Rodríguez-Cervantes PJ, Sancho-Bru JL, Barjau-Escribano A, Forner-Navarro L, Pérez-González A, Sánchez-Marín FT. Influence of prefabricated post dimensions on restored maxillary central incisors. J Oral Rehabil 2007; 34(2):141- 52. https://doi.org/10.1111/j.1365-2842.2006.01720.x

Galhano GÁ, Valandro LF, De Melo RM, Scotti R, Bottino MA. Evaluation of the flexural strength of carbon fiber-, quartz fiber-, and glass fiber-based posts. J Endod 2005; 31(3):209-11. https://doi.org/10.1097/01.don.0000137652.49748.0c

Baldissara P, Zicari F, Ciocca L, Zamboni SC, Valandro LF. Effect of fiber post emerging diameter on composite core stabilization. J Dent Res 2007; 86(Spec. Iss. A):2623.

Boschian Pest L, Guidotti S, Pietrabissa R, Gagliani M. Stress distribution in a post-restored tooth using the three- dimensional finite element method. J Oral Rehabil 2006; 33(9):690-7. https://doi.org/1010.1111/j.1365-2842.2006.01538.x

Okamoto K, Ino T, Iwase N, Shimizu E, Suzuki M, Satoh G, et al. Three-dimensional finite element analysis of stress distribution in composite resin cores with fiber posts of varying diameters. Dent Mater J 2008; 27(1):49-55. https://doi.org/10.4012/dmj.27.49

Jalalian E, Mirzaei M. In vitro evaluation of the effect of different diameters of quartz fiber posts on fracture resistance of dental roots. Rev Clín Pesq Odontol 2009; 5(1):29-36.

Barjau-Escribano A, Sancho-Bru JL, Forner-Navarro L, Rodríguez-Cervantes PJ, Perez-Gonzalez A, Sanchez-Marin FT. Influence of prefabricated post material on restored teeth: fracture strength and stress distribution. Oper Dent 2006; 31(1):47-54. https://doi.org/10.2341/04-169

Dilmener FT, Sipahi C, Dalkiz M. Resistance of three new esthetic post-and-core systems to compressive loading. J Prosthet Dent 2006; 95(2):130-6. https://doi.org/10.1016/j.prosdent.2005.11.013

Aksoy G, Cotert HS, Korkut L. Effect of an adhesive resin luting agent on the dowel-head retention of three different core materials. J Prosthet Dent 2005; 93(5):439-45. https://doi.org/10.1016/j.prosdent.2005.02.025

Lyons MF, Baxendale RH. A preliminary electromyographic study of bite force and jaw-closing muscle fatigue in human subjects with advanced tooth wear. J Oral Rehabil 1990; 17(4):311-8. https://doi.org/10.1111/j.1365-2842.1990.tb00014.x

Ng CC, Al-Bayat MI, Dumbrigue HB, Griggs JA, Wakefield CW. Effect of no ferrule on failure of teeth restored with bonded posts and cores. Gen Dent 2004; 52(2):143-6.

Downloads

Published

2022-03-18

How to Cite

Nokar, S. ., Mortazavi, M. S. ., & Niakan, S. . (2022). Effect of Glass Fiber Post Diameter on Fracture Resistance of Endodontically Treated Teeth. Pesquisa Brasileira Em Odontopediatria E Clínica Integrada, 20, e5413. Retrieved from https://revista.uepb.edu.br/PBOCI/article/view/1093

Issue

Section

Original Articles