Reliability of Linear and Curvilinear Measurements on Cone-Beam Computed Tomography Images for the Evaluation of Implant Sites and Jaw Pathologies

Authors

  • Mathangi Kumar
  • Medhini Madi
  • Kalyana Chakravarthy Pentapati
  • Ravindranath Vineetha

Keywords:

Dental Implantation, Jaw, Edentulous, Diagnostic Imaging, Pathology, Oral

Abstract

Objective: To evaluate the intra-examiner and inter-examiner reliability of linear and curvilinear measurements for the complete assessment of implant sites and jaw pathologies using Cone-Beam Computed Tomography (CBCT). Material and Methods: Fifty cone-beam computed tomographic images of patients were retrieved from the archives of Dentomaxillofacial Radiology. CBCT images taken for implant planning and evaluation of intrabony jaw pathologies (benign cyst/tumor) were included. Two expert oral and maxillofacial radiologists analyzed the images independently and made the measurements. The images for implant planning were analyzed for width, the height of the edentulous site, and the qualitative analysis of bone in the region. Jaw pathologies were assessed for linear dimensions and curvilinear measurements. Results: The inter-observer measurement error for implant site analysis ranged from 0.12 to 0.42 mm with almost perfect agreement (ICC: 0.94 to 1). The inter-observer measurement error for jaw pathology was 0.09 to 0.25 mm (ICC: 0.98-1). Curvilinear measurements showed perfect agreement between the observers. The intraobserver reliability for the various parameters used for the assessment of the implant site and jaw pathologies indicated almost perfect agreement. Conclusion: Reliability between the radiologists is high for various measurements on CBCT images taken for implant planning and jaw pathologies.

References

Pinsky HM, Dyda S, Pinsky RW, Misch KA, Sarment DP. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofac Radiol 2006; 35(6):410-6. https://doi.org/10.1259/dmfr/20987648

Safi Y, Kadkhodazadeh M, Esmaeil Nejad A, Vasegh Z, Amid R, Khalighi HR, et al. Reliability and reproducibility of linear measurements of alveolar ridges using cone-beam CT made by radiologists and periodontists. J Periodontol Implant Dent 2018; 7(2):35-9. https://doi.org/10.15171/jpid.2015.007

Abdinian M, Baninajarian H. The accuracy of linear and angular measurements in the different regions of the jaw in cone-beam computed tomography views. Dent Hypotheses 2017; 8(4):100-3. https://doi.org/10.4103/denthyp.denthyp_29_17

Al-Ekrish AA, Ekram M. A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofacial Radiol 2011; 40(2):67-75. https://doi.org/10.1259/dmfr/27546065

Bohner LOL, Tortamano P, Marotti J. Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters. Dentomaxillofac Radiol 2017; 46(5):20160377. https://doi.org/10.1259/dmfr.20160377

Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 2008; 37(1):10-7. https://doi.org/10.1259/dmfr/14140281

Weiss R 2nd, Read-Fuller A. Cone beam computed tomography in oral and maxillofacial surgery: an evidence-based review. Dent J 2019; 7(2):52. https://doi.org/doi:10.3390/dj7020052

Baumgaertel S, Palomo JM, Palomo L, Hans MG. Reliability and accuracy of cone-beam computed tomography dental measurements. Am J Orthod Dentofac Orthop 2009; 136(1):19-25. https://doi.org/10.1016/j.ajodo.2007.09.016

Menezes CC, Janson G, Massaro CDS, Cambiaghi L, Garib DG. Precision, reproducibility, and accuracy of bone crest level measurements of CBCT cross sections using different resolutions. Angle Orthod 2016; 86(4):535-42. https://doi.org/10.2319/040115-214.1

Aksoy S, Kelahmet U, Hincal E, Oz U, Orhan K. Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software. Biotechnol Biotechnol Equip 2016; 30(4):777-84. https://doi.org/10.1080/13102818.2016.1174077

Abramovitch K, Rice DD, Christiansen EL, Sabeti M. Reproducibility of linear alveolar ridge measurements in 2 dicom CBCT viewing software programs: a pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol 2019; 127(1):31. https://doi.org/10.1016/j.oooo.2018.07.012

Walter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med 1998; 17(1):101-10.

Misch CE, Judy KW. Classification of partially edentulous arches for implant dentistry. Int J Oral Implantol 1987; 4(2):7-13.

Shaabaninejad H, Sari AA, Rafiei S, Sari AM, Safi Y. The efficacy of CBCT for diagnosis and treatment of oral and maxillofacial disorders: a systematic review. J Islam Dent Assoc Iran 2014; 26(1):64-74.

Timock AM, Cook V, McDonald T, Leo MC, Crowe J, Benninger BL, et al. Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging. Am J Orthod Dentofac Orthop 2011; 140(5):734-44. https://doi.org/10.1016/j.ajodo.2011.06.021

Tolentino ES, Yamashita FC, de Albuquerque S, Walewski LA, Iwaki LCV, Takeshita WM, et al. Reliability and accuracy of linear measurements in cone-beam computed tomography using different software programs and voxel sizes. J Conserv Dent 2018; 21(6):607-12. https://doi.org/10.4103/JCD.JCD_314_18

de Souza KRS, Oltramari-Navarro PVP, Navarro RL, Conti ACCF, de Almeida MR. Reliability of a method to conduct upper airway analysis in cone-beam computed tomography. Braz Oral Res 2013; 27(1):48-54. https://doi.org/10.1590/S1806-83242013000100009

Zimmerman JN, Vora SR, Pliska BT. Reliability of upper airway assessment using CBCT. Eur J Orthod 2019; 41(1):101-8. https://doi.org/10.1093/ejo/cjy058

De Oliveira Lisboa C, Masterson D, Motta AFJ, Motta AT. Reliability and reproducibility of three-dimensional cephalometric landmarks using CBCT: a systematic review. J Appl Oral Sci 2015; 23(2):112-9. https://doi.org/10.1590/1678-775720140336

Golfeshan F, Miresmaili AF, Mosaddad SA. Reliability of impacted maxillary canine feature measurement obtained by CBCT. Ann Dent Spec 2018; 6(2):118-23.

Santos TDS, Gomes AC, De Melo D, Melo A, Cavalcante JR, De Araújo LC, et al. Evaluation of reliability and reproducibility of linear measurements of cone-beam-computed tomography. Indian J Dent Res 2012; 23(4):473-8. https://doi.org/10.4103/0970-9290.104952

Fokas G, Vaughn VM, Scarfe WC, Bornstein MM. Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: a systematic review. Clin Oral Implants Res 2018; 29 Suppl 16:393-415. https://doi.org/10.1111/clr.13142

Prashanti E, Vynne OJ, Annishka A, Fickry FSS, Naurah MA, Idiculla J, et al. A comparative cross-sectional study of pre-implant site assessment using ridge mapping and orthopantomography (OPG) with cone beam computed tomography (CBCT). Res J Pharm Biol Chem Sci 2016; 7(5):1185-92.

Luk LC, Pow EH, Li TK, Chow TW. Comparison of ridge mapping and cone beam computed tomography for planning dental implant therapy. Int J Oral Maxillofac Implants 2011; 26(1):70-4.

Schnutenhaus S, Graf M, Doering I, Luthardt RG, Rudolph H. Reproducibility of CBCT image analysis: a clinical study on intrapersonal and interpersonal errors in bone structure determination. Oral Radiol 2019; 35(2):152-8. https://doi.org/10.1007/s11282-018-0340-1

Kumar M, Shanavas M, Sidappa A, Kiran M. Cone beam computed tomography - know its secrets. J Int Oral Health 2015; 7(2):64-8.

Downloads

Published

2021-11-11

How to Cite

Kumar, M. ., Madi, M., Pentapati, K. C. ., & Vineetha, R. . (2021). Reliability of Linear and Curvilinear Measurements on Cone-Beam Computed Tomography Images for the Evaluation of Implant Sites and Jaw Pathologies. Pesquisa Brasileira Em Odontopediatria E Clínica Integrada, 21, e0125. Retrieved from https://revista.uepb.edu.br/PBOCI/article/view/635

Issue

Section

Original Articles